Best hmi panel provider: Determine the task that should be performed by human and computer respectively to complete the system function: There are two ways of task analysis. One is to start from the actual, through the analysis of the original application system in a manual or semi-manual state, it will be mapped to a set of similar tasks performed on the human-computer interface; the other is to study the system requirements specifications to derive a set of user tasks coordinated with the user model and system assumptions. Techniques such as stepwise refinement and object-oriented analysis are also applicable to task analysis. Stepwise refinement techniques can continuously divide the task into subtasks until the requirements for each task are clear; and object-oriented analysis techniques can be used to identify all the objective objects associated with the application and the actions associated with the objects. Discover additional info on hmi touch screen panel.
Response Speed Requirements: PLC is a general controller designed for industrial automation, and the response speed of different grades of PLC can generally meet the needs of its application range. If you wanna use plc across the range, or some functions or signals have special speed requirements, you should carefully consider the response speed of the plc, you can choose a plc with high-speed i/o processing function, or choose a plc with a fast response module and an interrupt input module.
Consistency principle: Including the consistency of color, operation area consistency, text consistency. That is, on the one hand, the interface color, shape and font are consistent with national, international or industry common standards. On the other hand, the interface color, shape and font are self-contained, and the color of different devices and their same design state should be consistent. Consistency in the aesthetic design of the interface details makes the operator feel comfortable when looking at the interface, so as not to distract his attention. Consistency also reduces errors for new operators, or for operators dealing with problems in emergency situations.
At the same time, because the electrical room has the characteristics of complex data processing, many inverters, strong voltage interference, and closed space, the requirements for the configuration, stability, and anti-interference of the body are high. The industrial-grade control equipment can be well integrated into the electrical cabinet control equipment, and can effectively control all electrical equipment, in the current era of big data and the Internet of Things, and even directly through remote control equipment, the electrical cabinet equipment monitoring. Find extra details on mochuan-drives.com.
Specifically, the two-way communication between the HCI user and the machine containing the computer, in a certain symbol and actions to achieve, such as hitting keys, moving the mouse, displaying symbols/graphics on the screen, etc. This process includes several sub-processes: identifying the interactive object – understanding the interactive object – grasping the object situation – information adaptation and feedback, etc.; and the human-machine interface is the communication media or means between the user and the machine system containing the computer, which is the software and hardware supporting the two-way information interaction between human and machine. Here the interface is defined as the media or means of communication, and its physical embodiment is the relevant supporting software and hardware, such as a graphic display terminal with a mouse, etc.
Supporting customized special technical parameters, special application scenarios or special process, special function realization, special performance, special application including shape, color etc. With NO MOQ before mass production. And will not accept to quantity production before customer 100% confirmation its stable quality to run in the device or equipment. Becuase quality is the soul of an enterprise. MochuanDrives customized pmsm motor mainly focuses on high-tech , high-end development, design, production, sales.
Typically, a heartbeat detection is used to define the BOOL, the HMI sets this point at a fixed frequency and the PLC resets when it receives a signal that the point is on. If no signal is received for that point to turn on for a period of time, e.g. 5s, the communication is considered broken. The PLC’s memory clock byte is passed to the touch panel interface, which uses a script to assign the value of this byte to an address in another PLC, which then determines whether the two scan cycles of the returned byte are the same. If so, the communication is interrupted.
Multi-touch capacitive hmi panel is new design and very popular with the market. Why? It is similar the Apple iPone in our life. Becuase its flexible multi touch, very high transmittance, Glass+Glass, anti-scratching, no drifting, IPS full view TFT lcd, high resolution, brightness, high speed and easy flow, supporting animation formats. The color of multitouch HMI is rich and the picture displayed is more delicate. Why many people follows iPhone, just becuase it can bring the users different and beyond imagination experience. Same reasons, why this type panel hmi is very popular in European and American market, just becuase it can bring the project, equipment different experience then to obtain more high value market and to be easily competitive the competitors. Maybe a little try, but to bring a large value, so why not try.
There are lots of temperature control in industry automation. It can select temperature module match the main module plc temperature controller, it also use independent temperature controller to control, both of them are to achieve temperature control. If wanna more flexibility in temperature control, maybe indenpendent temperature module is the first choice. Becuase it can operate without main module plc controller. Mochuan independent plc temperature module integrates an excellent self-tuning algorithm, and user can auto-tune with one button according to needs to accurately obtain PID parameters. Through rs485 communication port, communicate with upper computers of various brands, types of plc, touch screen hmi, configuration software and other upper computers to complete morecomplex logic temperature control.
The reason is rs232 is suitable for communication between local devices, and its transmission distance is generally not more than 15m, and rs232 only allows one-ton-one communication. But rs485 transmission distance is from tens of meters up to 2Km, and rs485 interface allows up to 255 slave station to be connected. These are required to be designed by our engineers, with whom to communicate, how many devices to communicate, how to achieve the final function, whether to take into consider the interference problems of the field environment etc. All of the above are considered.