Excellent dry type electrical transformers producing company: When is it not allowed to adjust the tap changer of the transformer on-load voltage regulating device? The on-load voltage regulating device is a common accessory equipment of the transformer, which is used to adjust the transformation ratio when the transformer is running, so as to achieve the purpose of adjusting the output voltage. When using the on-load pressure regulator, the following points need to be paid attention to: It is not allowed to operate under live conditions: because the transformer is working under live conditions, the tap changer of the on-load voltage regulating device will have an arc when it is adjusted, so it is not allowed to operate the tap changer under live conditions. Frequent adjustments are not allowed: frequent adjustments to the tap changer of the on-load tap changer may cause damage to the tap changer or poor contact, thereby affecting the normal operation of the transformer. Read more information at https://www.canwindg.com/products-detail-129320.
Current source inverter has a higher power factor: The current source inverter has a higher power factor, which can achieve higher power factor correction, thereby reducing grid harmonic pollution. However, since a higher power factor requires larger capacitor support, a transformer with a larger capacity needs to be selected to meet the power supply requirements of the capacitor. Current source inverter needs additional power supply: The circuit of current source inverter needs additional power supply to ensure the normal operation of the current loop control. These additional power sources need sufficient capacity to support, so a transformer with a larger capacity needs to be selected to meet the power supply requirements. Therefore, the current source inverter needs a larger transformer capacity to ensure the normal operation of the intermediate inductor, support the power supply of the capacitor and meet the power supply requirements. When selecting a transformer, it needs to be selected according to the actual electrical parameters and performance requirements to ensure the normal operation and stability of the inverter.
Maintaining high power quality requires careful management of harmonic currents and other potential disturbances on transmission lines. This is crucial not only for the efficient performance of transformer core cutting machine but also for the overall reliability and safety of the power system. Voltage unbalance is a significant power quality issue that can severely affect the efficiency of electrical equipment. It occurs when the voltages or currents in a three-phase system are not equal in magnitude or are not separated by exactly 120 degrees. Voltage unbalance can cause several problems in electrical equipment. For instance, it can lead to a decrease in the efficiency of electric motors by causing a reduction in torque and an increase in vibration and noise. This not only affects the performance of the motor but also shortens its lifespan. Similarly, voltage unbalance can also reduce the efficiency of transformers, leading to increased losses and overheating.
A China slitting line produces longitudinal cuts in a master coil of steel to predetermined narrower widths. These smaller coils are then sent to downstream operations such as metal stampers, tube producers or roll forming houses that will use the material in their final product. Customized slitting line machine equipment mainly includes the following: Loading trolley, double support uncoiler, feeding device, traction leveling machine, trimming shearing machine, deviation correction feeding device, longitudinal shear line, waste edge winder, feed rack, pre separation device, tensioner, feeding roller, winding shearing machine, steering drum, rear axle, discharge trolley, winding auxiliary support, hydraulic system and electrical system, etc.
Founded in 2002, CANWIN Automatic Equipment Manufacturing Co., Ltd. is one of the largest electrical equipment manufacturers in China. We focus on the R&D for Silicon Steel Sheet Cut To Length Lines, Silicon Steel Sheet Slitting Line, Transformer Foil Winding Machines and other equipment. Adhering to the business route of High-end Manufacturing+ Smart Equipment + Smart Factory, we established the Silicon Steel Sheet Engineering Technology Research Center, Metal Strip Precision Cutting Key Technology & Equipment Engineering Center, and Power Transformer Intelligent Manufacturing Center to improve the shearing precision and speed. We have contributed the upgrading and innovating of global power industry institutions.
The cooling methods are divided into natural air cooling (AN) and forced air cooling (AF). When air cooled naturally, the transformer can run continuously for a long time under rated capacity. When forced air cooling, transformer output capacity can be increased by 50%. Suitable for intermittent overload operation, or emergency overload operation; Because the load loss and impedance voltage increase greatly during overload, it is in non-economic operation state, so it should not be in continuous overload operation for a long time.Welcome to inquiry price for dry type substation transformer.
The transformer coils are referred to as the primary and secondary windings. When applying AC current to the primary winding of the transformer, the transformer coil creates a pulsing magnetic field. The core of the transformer works to direct the path of the magnetic field between the primary and secondary coils to prevent wasted energy.The machine is a very powerful and versatile machine which can wind a wide range of HV coils for distribution transformers using round and rectangular wires. It is fully automatic with paper strip winding.Winding material lnsulated with an epoxy resin -environmentally friendly.
As a result of mutual inductance, a transformer produces a transformed voltage or current when the magnetic flux produced by one winding (primary winding) links with another winding (secondary winding). There is a magnetic coupling between these two windings, and they are electrically isolated. In addition, magnetic reluctance is also known as opposition to magnetic flux flow. If, for example, the magnetic flux produced by a primary winding passes through air or any nonferrous material in order to reach a secondary winding in a transformer, it would result in a reduction in magnetic flux. Due to the high reluctance of air or nonferrous materials, it will reduce magnetic flux. Read even more information at https://www.canwindg.com/
Epoxy resin is non – combustible, flame retardant, self – extinguishing solid insulation material, safe and clean. It is also a solid insulation material with proven insulation and heat dissipation technology for more than 40 years.Epoxy resin products can be used for dry type transformer, for insulation parts, for instrument transformer, for electrical composite parts and for room temperature curing. Epoxy resin dry transformer uses epoxy resin as insulation material. The high and low voltage windings are made of copper tape (foil), industrial epoxy resin is poured in vacuum and cured, forming a high strength FRP body structure. Insulation grade F, H. Epoxy resin dry transformer has the characteristics of good electrical performance, strong resistance to lightning impact, strong resistance to short circuit, small size and light weight. Temperature display controller can be installed to display and control the operating temperature of the transformer winding to ensure the normal service life of the transformer.
The main pillar of the smart grid is the smart substation, which is not only an important hub for power transmission and distribution, but also directly affects the operational and monitoring capabilities of the smart grid through its operational safety and stability. Through the network, information can be exchanged, and the transformer can share information with the process layer and the station control layer. On the premise of ensuring product performance, the integration of monitoring, control, measurement, protection, and metering is designed to achieve the integration of transformer components with actuators, sensors, and transformers.
Connection group label: According to the phase relationship between the primary and secondary windings of the transformer, the transformer windings are connected into various combinations, which are called the connection group of the windings. In order to distinguish different connection groups, the clock notation is often used, that is, the phasor of the line voltage on the high-voltage side is used as the long hand of the clock, fixed at 12, and the phasor of the line voltage on the low-voltage side is used as the short hand of the clock. The number of the short hand indicates the connection group label. For example, Dyn11 indicates that the primary winding is (triangle) connected, and the secondary winding is (star) connected with a center point, and the group number is (11) points.